DIMENSIONS AND DISTANCES TO BE
RESPECTED (mm)
INJECTOR TABLE
INJECTOR TABLE CATEGORY: II2H3+
POWER SUPPLY: 230 V ~ 50 Hz
If a hood is installed above the hob, refer to the hood
instructions for the correct distance.
Ty p e o f g a s u se d
Ty p e o f
burner
Injector
marking
Nominal
heating
capacity
[kW]
Nominal
consumption
Reduced
heating
capacity
[kW]
Gas pressure
(mbar)
min. nom. max.
NATURAL GAS
(Methane) G20
Wok
semi-rapid
139
95
3.70
1.65
352 l/h
157 l/h
1.40
0.40
17 20 25
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Wok
semi-rapid
92
65
3.70
1.65
269 g/h
120 g/h
1.40
0.40
20 28-30 35
LIQUEFIED
PETROLEUM GAS
(Propane) G31
92
65
269 g/h
118 g/h
25 37 45
Wok
semi-rapid
3.70
1.65
1.40
0.40
Ty p e o f g a s u s e d
Model
configuration
Nominal
heating
capacity kW
Nominal total
consumption
Air necessary (m)
for combustion of
1 m
3
of gas
G20 20 mbar
G30 28-30 mbar
G31 37 mbar
3 burners
3 burners
3 burners
7.00
7.00
7.00
583 l/h
509 g/h
505 g/h
9.52
30.94
23.80