ADJUSTING MINIMUM GAS SETTING OF TAPS
To ensure that the minimum setting is correctly adjusted, remove the
knob and proceed as follows:
tighten screw to reduce the flame height (-)
loosen screw to increase the flame height (+)
The adjustment must be performed with the tap in minimum gas
setting position (small flame) .
The primary air of the burners does not need to be adjusted.
At this stage, light up the burners and turn the knobs from max
position to minimum position to check flame stability.
Upon completion of adjustment, reseal using sealing wax or an
equivalent material.
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the
correct distance.
INJECTORS TABLE CATEGORY II2H3+
ELECTRIC SUPPLY: 230V ~ 50Hz
Ty p e o f g a s us e d Ty p e o f
burner
Injector
marking
Rated
thermal
flow rate
kW
Rated
consumption
Reduced
heat
capacity
kW
Gas pressure mbar
min. rat. max.
NATURAL GAS
(Methane) G20
rapid
semirapid
auxiliary
Y 115
H2 98
X 72
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
0.60
0.35
0.30
17 20 25
LIQUEFIED
PETROLEUM GAS
(Butane) G30
rapid
semirapid
auxiliary
87
65
50
3.00
1.65
1.00
218 g/h
120 g/h
73 g/h
0.60
0.35
0.30
20 28-30 35
LIQUEFIED
PETROLEUM GAS
(Propane) G31
rapid
semirapid
auxiliary
87
65
50
3.00
1.65
1.00
214 g/h
118 g/h
71 g/h
0.60
0.35
0.30
25 37 45
Type of gas used Model configuration
4 burners
Rated thermal flow
rate kW
To t a l r a t e d
consumption
Air required (m
3
) for
burning 1m
3
of gas
G20 20 mbar 1 R - 2 SR - 1 AUX 7.30 695 l/h 9.52
G30 28-30 mbar 1 R - 2 SR - 1 AUX 7.30 531 g/h 30.94
G31 37 mbar 1 R - 2 SR - 1 AUX 7.30 521 g/h 23.80
Przeglądanie stron 3
1 2 3 4

Komentarze do niniejszej Instrukcji

Brak uwag