Whirlpool AKM 292/IX Instrukcja Obsługi Strona 4

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 13
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 3
20
DIMENSIONS AND DISTANCES TO BE
RESPECTED (mm)
INJECTOR TABLE
INJECTOR TABLE CATEGORY: II2H3+ IT + UK
POWER SUPPLY: 230 V ~ 50 Hz
If a hood is installed above the hob, refer to the hood
instructions for the correct distance.
Type of gas used
Type of
burner
Injector
marking
Nominal
heating
capacity
[kW]
Nominal
consumption
Reduced
heating
capacity
[kW]
Gas pressure
(mbar)
min. nom. max.
NATURAL GAS
(Methane)
G20
rapid
semi-rapid
auxiliary
128
95
78
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
0.90
0.40
0.30
17 20 25
LIQUEFIED
PETROLEUM GAS
(Butane)
G30
rapid
semi-rapid
auxiliary
85
65
50
3.00
1.65
1.00
218 g/h
120 g/h
73 g/h
0.90
0.40
0.30
25 30 35
LIQUEFIED
PETROLEUM GAS
(Propane) G31
rapid
semi-rapid
auxiliary
85
65
50
3.00
1.65
1.00
214 g/h
118 g/h
71 g/h
0.90
0.40
0.30
25 30 35
Type of gas used
Model
configuration
Nominal
heating
capacity kW
Nominal total
consumption
Air necessary (m)
for combustion of
1m
3
of gas
G20 20 mbar
G30
30 mbar
G31
30 mbar
4 burners
4 burners
4 burners
7.3
7.3
7.3
695 l/h
531 g/h
521 g/h
9.52
30.94
23.80
Przeglądanie stron 3
1 2 3 4 5 6 7 8 9 ... 12 13

Komentarze do niniejszej Instrukcji

Brak uwag