19
INSTALLATION
Replacing the injectors (see table in enclosed product
description sheet)
1.
Remove grids
A
.
2.
Extract burners
B
.
3.
Using a socket spanner of the appropriate size,
C
,
unscrew the injector to be replaced.
4.
Replace it with the injector suitable for the new type of gas.
5.
Re-assemble the injector in
D
.
6.
For models equipped with a triple crown burner, proceed as
shown in figure.
Remove the two screws
F
followed by the cap
G
then
replace both injectors
D
as previously described.
Replace the cap
G
, ensuring the seal is properly
positioned before attempting to use the cooktop.
7.
Before installing the cooktop, remember to affix the gas
calibration plate supplied with the injectors in such a way that
it covers the existing information relating to gas calibration.
Adjusting minimum gas setting of taps
To ensure that the minimum setting is correctly adjusted,
remove knob
E
and proceed as follows:
tighten (-) to reduce the height of the flame;
loosen (+) to increase the height of the flame.
The adjustment must be performed with the tap in minimum gas
setting position (small flame) .
3gb66034.fm Page 19 Wednesday, May 28, 2003 5:50 PM