EN 6
B
R = Min. 6,5 mm
Max. 8 mm
490 mm
750 mm
0
+2
0
+2
Min. 70 mm
513 mm
Min. 70 mm
773 mm
0
+2
0
+2
750 mm
490 mm
0
+2
0
+2
482 mm
742 mm
510 mm
42/46 mm
R = 11,5 mm
R = Min. 6,5 mm
6 mm
min 20 mm
770 mm
770 X 510 mm
STANDARD INSTALLATION
FLUSH INSTALLATION
• Install a separator panel under the hob;
• Do not t the separator panel if an undertop oven is installed;
• He lower part of the product must not be accessible after installation.
IMPORTANT:
• The distance between the underside of the appliance and
the separator panel must respect the dimensions given
in the gure;
• If an oven is installed under the hob, make sure the oven
is equipped with a cooling system;
• Do not install the hob above a dishwasher or washing-
machine, so that the electronic circuits do not come into
contact with steam or moisture which could damage them.
min. 20 mm
PLACING THE HOB
After the electrical connection (see the chapter “Electrical connection”) position each xing clips on the dedicated slots on the lateral sides of the hob as shown
in the picture. Then push the hob inside the cut out and check that the glass is at and parallel to the worktop. The xing clips are designed for every type of
worktop material (wood, marble, etc).
IMPORTANT:
• Use protective gloves during hob installation.
4x