GB
Other types of connection
! The cable provided is not suitable for the following
types of installation.
If the mains supply corresponds with one of the
following:
Voltage and mains frequency
 400V 2 - N ~ 50 Hz
 230V 3 ~ 50 Hz
 230V 2 + 2 - N ~ 50 Hz
proceed as follows:
1. Use a suitable supply cable, H05RR-F or higher, with
the right dimensions (cable section: 1.5 mm).
2. To open the terminal board, insert a screwdriver into
the side tabs of the cover (see Terminal board picture).
3. Loosen the cable clamp screw and the terminal board
screws according to the type of connection required and
position the connection supports as shown in the
following table and diagrams.
4. Position the wires according to the following table and
diagrams and connect the appliance by tightening all
the screws for the springs as much as possible.
Two-phase
5. Secure the power supply cable by fastening the clamp
screw then put the cover back on.
Connecting the supply cable to the mains
If the appliance is being connected directly to the mains
an omnipolar circuit-breaker must be installed with a
minimum opening of 3 mm between contacts.
! The installer must ensure that the correct electrical
connection has been made and that it is compliant with
safety regulations.
Before connecting to the power supply, make sure that:
The appliance is earthed and the plug is compliant
with the law.
The socket can withstand the maximum power of the
appliance, which is indicated on the attached data
plate.
The power supply voltage is in the range between the
values indicated on the data plate.
The socket is compatible with the plug of the
appliance. If the socket is incompatible with the plug,
ask an authorised technician to replace it. Do not use
extension cords or multiple sockets.
! Once the appliance has been installed, the power
supply cable and the electrical socket must be easily
accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced by
authorised technicians only.
! The manufacturer declines any liability should these
safety measures not be observed.
Three-phase 400 2+N
Three-phase 230
Phase Neutral EarthPhase Neutral
5
1
2
3
4
5
1
2
3
4
U-bolt
connection
support
PhasePhase Neutral Earth
5
1
2
3
4
U-bolt
connection
support
Phase PhasePhase Earth
Voltage and
mains
frequency
Electrical connections
Terminal
board
400V 2-N ~
50 Hz
Three-phase
400 2+N
230V 3 ~ 50 Hz
Three-phase
230
230V 2+2-N ~
50 Hz
Two-phase
L1
L2
N2N1
1 2 3 4
5
L1 L2 L3
1 2 3 4 5
L1 L2 N
1 2 3 4 5
Przeglądanie stron 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 51 52

Komentarze do niniejszej Instrukcji

Brak uwag