42
Notes:
If the connecting cable is not long enough, please contact the authorized service centre for a
length of special cable. No joints are allowed in the cable.
• Make sure to connect the cable correctly. Incorrect connection will cause malfunction of
some electrical parts.
• Tighten the terminal screw to prevent slack.
• After tightening the screw, gently pull the cable taut.
• Incorrect connection of grounding cable may cause electrocution.
• Make sure to fasten the junction cover plate securely and press it tightly against the
connecting cable. Improper fastening may allow dust or water to enter or expose
connecting terminal directly to external forces, and fire or electrocution could occur.
Installing Indoor Unit
•
Fitting pipe can come from four directions, i.e. right, rear right, left and rear left.
1.
When installing the pipe on the left or right side, trim off any extra pipe left at the pipe outlet stub on
the base of the unit. (See Fig. 1).
•
When drawing out the power line, cut extra part 1. When drawing out the connecting pipe and the
power line, cut extra parts 1 & 2 (or 1, 2 & 3);
2.
Pull the fitting pipe out of the bottom case. Use adhesive tape to bind the fitting pipe, electrical cable
and drain hose properly and then pass them through the fitting pipe hole (See Fig. 2).
3.
Hang the claws on the back of the indoor unit to the hook on the wall-mounting frame. Move the
unit left and right to control that it is steady. (See Fig. 3).
4.
The installation height of the indoor unit must be at least 2.3 m.
Fitting pipe on air side
Fig. 1
Electrical cable for
external connection
Fitting pipe
on liquid side
Extra Part 3
Extra Part 2
Extra Part 1
Finally, wrap with
adhesive tape.
Drainage
Pipe
Right rear
Fig. 2
Fixing Hook
Fig. 3
Mounting
Plate
Mounting
Plate
Left rear
Heat insulation of
fitting pipe on air side
Heat insulation
of fitting pipe on
liquid or side
Right
Left