+3+E2II YROGETACELBAT SROTCEJNI
Type of gas
used
Type of burnerInjector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity
kW
Gas pressure
mbar
.xam.tar.nimRFEBWk
NATURAL GAS
(Methane) G20
Rapid 129 B3.00286 l/h0.800.60
17 20 25Semi-rapid971.65157 l/h0.450.35
Auxiliary74 B1.0095 l/h 0.35 0.30
NATURAL GAS
(Methane) G25
Rapid 129 B3.00332 l/h0.60
20 25 30Semi-rapid971.65183 l/h0.35
Auxiliary74 B1.00111 l/h0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Rapid863.00218 g/h0.60
20 28-30 35Semi-rapid651.65120 g/h0.35
Auxiliary501.0073 g/h0.30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Rapid863.00214 g/h0.60
25 37 45Semi-rapid651.65118 g/h 0.35
Auxiliary501.00 71 g/h0.30
Type of gas used Model conguration
4 BURNERS
Rated thermal
ow rate (kW)
Total rated
consumption
Air required (m
3
) for
burning1m
3
of gas
G20 20 mbar1 R - 2 SR - 1 AUX 7.30 695 l/h9.52
G25 25 mbar 1 R - 2 SR - 1 AUX 7.30 809 l/h8.187
G30 28-30 mbar 1 R - 2 SR - 1 AUX 7.30 531 g/h 30.94
G31 37 mbar1 R - 2 SR - 1 AUX 7.30 521 g/h23.80