Whirlpool AKR 352/IX Instrukcja Obsługi Strona 6

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 6
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 5
The burner might go out when the knob is released. This means that the safety device has not warmed up enough. In this case, repeat the operations
described above.
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: if the distance “A” between the wall cabinets is
between 600 mm and 730 mm, the height “B” must be a
minimum of 530 mm.
if the distance “A” between the wall cabinets is greater
than the width of the hob, the height “B” must be a
minimum of 400 mm.
In case of installation of a hood above the hob, please refe
r
to the hood instructions fot the correct distance.
+3H2II YROGETACELBAT SROTCEJNI
Type of gas
used
Type of burner Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity
Gas pressure
mbar
.xam.tar.nimWkWk
NATURAL GAS
(Methane) G20
Power Burner 138 A3.50333 l/h 1.55
17 20 25Semi-rapid971.75167 l/h0.35
Auxiliary 74 B 1.0095 l/h0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Power Burner P 93 3.50 254 g/h1.55
20 28-30 35Semi-rapid 65 1.75 127 g/h 0.35
Auxiliary501.0073 g/h0.30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Power Burner P 93 3.50 250 g/h1.55
25 37 45Semi-rapid 65 1.75 125 g/h 0.35
Auxiliary501.0071 g/h0.30
Type of gas used Model conguration
4 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m
3
) for
burning1m
3
of gas
G20 25.9h/l 26700.8XUA 1 - RS 2 - C2 BP 1rabm 02
G30 28-30 mbar 1 PB 2C - 2 SR - 1 AUX8.00581 g/h 30.94
G31 37 mbar 1 PB 2C - 2 SR - 1 AUX8.00571 g/h 23.80
ELECTRIC SUPPLY: 220-240 V ~ 50-60 Hz 0,6W